View quote "Outdoor Cabinets – Solar Panel Structural" was successfully added to your enquiry.
Six-tap stainless steel commercial water cooler with open cabinet doors showing dual cooling tanks, compressors and filtration components.
Six-tap stainless steel commercial water cooler with open cabinet doors showing dual cooling tanks, compressors and filtration components.HCW-6K 100L stainless steel commercial cold water dispenser with four dispensing taps and dual cooling tanksSix-tap stainless steel industrial water cooler installed under a blue steel-framed outdoor sunshade shelter with corrugated metal roof.Two chrome-plated cold water dispensing taps with running water on a commercial stainless steel water cooler.

HCW-6K High Capacity Cold Water Cooler Dispenser – 100L Stainless Steel

HCW-6K High Capacity Cold Water Dispenser – 100L Stainless Steel

The HCW-6K is a high-capacity commercial cold water dispenser designed for factories, industrial facilities, offices, schools and other high-demand environments.

Featuring a 100-litre dual-tank cooling system, four dispensing taps, upgraded high-flow ultrafiltration with activated-carbon post-filtration and integrated UV sterilisation, the unit delivers a rated cold-water supply of 200 litres per hour at 5–7°C under specified operating conditions.

Constructed with a durable brushed SUS304 stainless steel cabinet, the dispenser is designed for high-volume drinking water applications, convenient maintenance and reliable operation.

Key Features

  • 100L Total Tank Capacity – Dual 50-litre cold-water tanks for high-volume applications.
  • 200L/H Rated Cold Water Supply – Designed for commercial and industrial drinking water demand.
  • 5–7°C Cold Water Temperature – Chilled water under specified operating conditions.
  • Four Dispensing Taps – Simultaneous dispensing with approximately 1 litre/minute per tap and 4 litres/minute combined flow.
  • High-Flow Ultrafiltration – Upgraded 1000L SUS304 stainless steel ultrafiltration system for improved water filtration and tank replenishment.
  • Activated-Carbon Filtration – 10-inch post-carbon filter for additional water treatment.
  • 14W UV Sterilisation – Integrated inline ultraviolet water treatment.
  • SUS304 Stainless Steel Cabinet – Durable brushed stainless steel construction.
  • Dual Cooling System – Two 50-litre cold-water tanks with R290 refrigeration.
  • Custom Handling Options – Optional stainless steel raised base frame, forklift handling provisions and lifting eyes.
  • Backflow Prevention – Optional inlet non-return valve to help prevent reverse water flow.

Technical Specifications

Item Specification
Model HCW-6K
Type Free-Standing Cold Water Dispenser
Cabinet Material SUS304 Stainless Steel
Surface Finish Brushed Stainless Steel
Cabinet Dimensions (L × W × H) 1400 × 600 × 1470 mm
Cooling Power 1200 W
Refrigerant R290
Power Supply 220V AC, 50Hz
Plug Type UK Plug
Water Source Municipal Tap Water
Inlet Water Pressure 0.2–0.6 MPa (2–6 bar)
Dispensing Taps 4 Cold Water Taps
Combined Dispensing Flow Approx. 4 L/min
Cold Water Temperature 5–7°C
Tank Capacity 100L (50L + 50L)
Rated Cold Water Supply 200 L/hour
Ultrafiltration 1000L SUS304 UF System
Carbon Filtration 10-inch Post-Carbon Filter
UV Treatment 14W Inline UV Steriliser
Recommended Users 200–250 Persons
Lead Time 6–8 Weeks

Applications

  • Factories and Industrial Facilities
  • Offices and Commercial Buildings
  • Schools and Educational Institutions
  • Worker Facilities and Staff Canteens
  • Marine and Shipyard Facilities
  • Public Facilities and High-Traffic Areas
  • Industrial Drinking Water Stations

Customisation Options

Sunny Metal & Engineering Pte Ltd provides customised stainless steel fabrication and equipment integration solutions to suit specific project requirements.

Available customisation options include:

  • Stainless steel cabinet dimensions and configurations
  • Custom raised stainless steel base frames
  • Forklift handling provisions
  • Lifting eyes for equipment handling
  • Dispensing tap arrangements
  • Water tank and filtration configurations
  • Inlet non-return valves for backflow prevention
  • Custom installation and mounting requirements

Installation Requirements

  • Install in a sheltered, well-ventilated location.
  • Avoid direct sunlight and rain exposure.
  • Recommended clearance of 1 metre on each side for ventilation.
  • Recommended inlet-water temperature below 35°C.
  • Recommended ambient temperature below 40°C.
  • Required inlet water pressure: 0.2–0.6 MPa.
  • Suitable water supply and electrical connections are required.

Maintenance

  • Ultrafiltration Membrane: Periodic cleaning as required.
  • Activated-Carbon Filter: Recommended replacement every 6–12 months, depending on water quality and usage.
  • General Maintenance: Regular inspection and servicing of the cooling, filtration and dispensing systems.

Important Notes

Cooling performance depends on inlet-water temperature, ambient conditions and usage.

Specifications and dimensions may vary according to customised configurations.

Installation, commissioning, testing and certification are excluded unless specifically quoted.